306 lines
8.3 KiB
C
306 lines
8.3 KiB
C
// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* Copyright (c) 2023, Nikita Travkin <nikita@trvn.ru>
|
|
*/
|
|
|
|
#include <linux/errno.h>
|
|
#include <linux/module.h>
|
|
#include <linux/platform_device.h>
|
|
#include <linux/power_supply.h>
|
|
#include <linux/property.h>
|
|
#include <linux/regmap.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/delay.h>
|
|
#include <linux/interrupt.h>
|
|
#include <linux/timekeeping.h>
|
|
#include <linux/mod_devicetable.h>
|
|
|
|
#define PM8916_PERPH_TYPE 0x04
|
|
#define PM8916_BMS_VM_TYPE 0x020D
|
|
|
|
#define PM8916_SEC_ACCESS 0xD0
|
|
#define PM8916_SEC_MAGIC 0xA5
|
|
|
|
#define PM8916_BMS_VM_STATUS1 0x08
|
|
#define PM8916_BMS_VM_FSM_STATE(x) (((x) & 0b00111000) >> 3)
|
|
#define PM8916_BMS_VM_FSM_STATE_S2 0x2
|
|
|
|
#define PM8916_BMS_VM_MODE_CTL 0x40
|
|
#define PM8916_BMS_VM_MODE_FORCE_S3 (BIT(0) | BIT(1))
|
|
#define PM8916_BMS_VM_MODE_NORMAL (BIT(1) | BIT(3))
|
|
|
|
#define PM8916_BMS_VM_EN_CTL 0x46
|
|
#define PM8916_BMS_ENABLED BIT(7)
|
|
|
|
#define PM8916_BMS_VM_FIFO_LENGTH_CTL 0x47
|
|
#define PM8916_BMS_VM_S1_SAMPLE_INTERVAL_CTL 0x55
|
|
#define PM8916_BMS_VM_S2_SAMPLE_INTERVAL_CTL 0x56
|
|
#define PM8916_BMS_VM_S3_S7_OCV_DATA0 0x6A
|
|
#define PM8916_BMS_VM_BMS_FIFO_REG_0_LSB 0xC0
|
|
|
|
/* Using only 1 fifo is broken in hardware */
|
|
#define PM8916_BMS_VM_FIFO_COUNT 2 /* 2 .. 8 */
|
|
|
|
#define PM8916_BMS_VM_S1_SAMPLE_INTERVAL 10
|
|
#define PM8916_BMS_VM_S2_SAMPLE_INTERVAL 10
|
|
|
|
struct pm8916_bms_vm_battery {
|
|
struct device *dev;
|
|
struct power_supply *battery;
|
|
struct power_supply_battery_info *info;
|
|
struct regmap *regmap;
|
|
unsigned int reg;
|
|
unsigned int last_ocv;
|
|
time64_t last_ocv_time;
|
|
unsigned int vbat_now;
|
|
};
|
|
|
|
static int pm8916_bms_vm_battery_get_property(struct power_supply *psy,
|
|
enum power_supply_property psp,
|
|
union power_supply_propval *val)
|
|
{
|
|
struct pm8916_bms_vm_battery *bat = power_supply_get_drvdata(psy);
|
|
struct power_supply_battery_info *info = bat->info;
|
|
int supplied;
|
|
|
|
switch (psp) {
|
|
case POWER_SUPPLY_PROP_STATUS:
|
|
supplied = power_supply_am_i_supplied(psy);
|
|
|
|
if (supplied < 0 && supplied != -ENODEV)
|
|
return supplied;
|
|
else if (supplied && supplied != -ENODEV)
|
|
val->intval = POWER_SUPPLY_STATUS_CHARGING;
|
|
else
|
|
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
|
|
return 0;
|
|
|
|
case POWER_SUPPLY_PROP_HEALTH:
|
|
if (bat->vbat_now < info->voltage_min_design_uv)
|
|
val->intval = POWER_SUPPLY_HEALTH_DEAD;
|
|
else if (bat->vbat_now > info->voltage_max_design_uv)
|
|
val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
|
|
else
|
|
val->intval = POWER_SUPPLY_HEALTH_GOOD;
|
|
return 0;
|
|
|
|
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
|
|
val->intval = bat->vbat_now;
|
|
return 0;
|
|
|
|
case POWER_SUPPLY_PROP_VOLTAGE_OCV:
|
|
/*
|
|
* Hardware only reliably measures OCV when the system is off or suspended.
|
|
* We expose the last known OCV value on boot, invalidating it after 180 seconds.
|
|
*/
|
|
if (ktime_get_seconds() - bat->last_ocv_time > 180)
|
|
return -ENODATA;
|
|
|
|
val->intval = bat->last_ocv;
|
|
return 0;
|
|
|
|
default:
|
|
return -EINVAL;
|
|
}
|
|
}
|
|
|
|
static enum power_supply_property pm8916_bms_vm_battery_properties[] = {
|
|
POWER_SUPPLY_PROP_STATUS,
|
|
POWER_SUPPLY_PROP_VOLTAGE_NOW,
|
|
POWER_SUPPLY_PROP_VOLTAGE_OCV,
|
|
POWER_SUPPLY_PROP_HEALTH,
|
|
};
|
|
|
|
static irqreturn_t pm8916_bms_vm_fifo_update_done_irq(int irq, void *data)
|
|
{
|
|
struct pm8916_bms_vm_battery *bat = data;
|
|
u16 vbat_data[PM8916_BMS_VM_FIFO_COUNT];
|
|
int ret;
|
|
|
|
ret = regmap_bulk_read(bat->regmap, bat->reg + PM8916_BMS_VM_BMS_FIFO_REG_0_LSB,
|
|
&vbat_data, PM8916_BMS_VM_FIFO_COUNT * 2);
|
|
if (ret)
|
|
return IRQ_HANDLED;
|
|
|
|
/*
|
|
* The VM-BMS hardware only collects voltage data and the software
|
|
* has to process it to calculate the OCV and SoC. Hardware provides
|
|
* up to 8 averaged measurements for software to take in account.
|
|
*
|
|
* Just use the last measured value for now to report the current
|
|
* battery voltage.
|
|
*/
|
|
bat->vbat_now = vbat_data[PM8916_BMS_VM_FIFO_COUNT - 1] * 300;
|
|
|
|
power_supply_changed(bat->battery);
|
|
|
|
return IRQ_HANDLED;
|
|
}
|
|
|
|
static const struct power_supply_desc pm8916_bms_vm_battery_psy_desc = {
|
|
.name = "pm8916-bms-vm",
|
|
.type = POWER_SUPPLY_TYPE_BATTERY,
|
|
.properties = pm8916_bms_vm_battery_properties,
|
|
.num_properties = ARRAY_SIZE(pm8916_bms_vm_battery_properties),
|
|
.get_property = pm8916_bms_vm_battery_get_property,
|
|
};
|
|
|
|
static int pm8916_bms_vm_battery_probe(struct platform_device *pdev)
|
|
{
|
|
struct device *dev = &pdev->dev;
|
|
struct pm8916_bms_vm_battery *bat;
|
|
struct power_supply_config psy_cfg = {};
|
|
int ret, irq;
|
|
unsigned int tmp;
|
|
|
|
bat = devm_kzalloc(dev, sizeof(*bat), GFP_KERNEL);
|
|
if (!bat)
|
|
return -ENOMEM;
|
|
|
|
bat->dev = dev;
|
|
|
|
bat->regmap = dev_get_regmap(pdev->dev.parent, NULL);
|
|
if (!bat->regmap)
|
|
return -ENODEV;
|
|
|
|
ret = device_property_read_u32(dev, "reg", &bat->reg);
|
|
if (ret < 0)
|
|
return -EINVAL;
|
|
|
|
irq = platform_get_irq_byname(pdev, "fifo");
|
|
if (irq < 0)
|
|
return irq;
|
|
|
|
ret = devm_request_threaded_irq(dev, irq, NULL, pm8916_bms_vm_fifo_update_done_irq,
|
|
IRQF_ONESHOT, "pm8916_vm_bms", bat);
|
|
if (ret)
|
|
return ret;
|
|
|
|
ret = regmap_bulk_read(bat->regmap, bat->reg + PM8916_PERPH_TYPE, &tmp, 2);
|
|
if (ret)
|
|
goto comm_error;
|
|
|
|
if (tmp != PM8916_BMS_VM_TYPE)
|
|
return dev_err_probe(dev, -ENODEV, "Device reported wrong type: 0x%X\n", tmp);
|
|
|
|
ret = regmap_write(bat->regmap, bat->reg + PM8916_BMS_VM_S1_SAMPLE_INTERVAL_CTL,
|
|
PM8916_BMS_VM_S1_SAMPLE_INTERVAL);
|
|
if (ret)
|
|
goto comm_error;
|
|
ret = regmap_write(bat->regmap, bat->reg + PM8916_BMS_VM_S2_SAMPLE_INTERVAL_CTL,
|
|
PM8916_BMS_VM_S2_SAMPLE_INTERVAL);
|
|
if (ret)
|
|
goto comm_error;
|
|
ret = regmap_write(bat->regmap, bat->reg + PM8916_BMS_VM_FIFO_LENGTH_CTL,
|
|
PM8916_BMS_VM_FIFO_COUNT << 4 | PM8916_BMS_VM_FIFO_COUNT);
|
|
if (ret)
|
|
goto comm_error;
|
|
ret = regmap_write(bat->regmap,
|
|
bat->reg + PM8916_BMS_VM_EN_CTL, PM8916_BMS_ENABLED);
|
|
if (ret)
|
|
goto comm_error;
|
|
|
|
ret = regmap_bulk_read(bat->regmap,
|
|
bat->reg + PM8916_BMS_VM_S3_S7_OCV_DATA0, &tmp, 2);
|
|
if (ret)
|
|
goto comm_error;
|
|
|
|
bat->last_ocv_time = ktime_get_seconds();
|
|
bat->last_ocv = tmp * 300;
|
|
bat->vbat_now = bat->last_ocv;
|
|
|
|
psy_cfg.drv_data = bat;
|
|
psy_cfg.of_node = dev->of_node;
|
|
|
|
bat->battery = devm_power_supply_register(dev, &pm8916_bms_vm_battery_psy_desc, &psy_cfg);
|
|
if (IS_ERR(bat->battery))
|
|
return dev_err_probe(dev, PTR_ERR(bat->battery), "Unable to register battery\n");
|
|
|
|
ret = power_supply_get_battery_info(bat->battery, &bat->info);
|
|
if (ret)
|
|
return dev_err_probe(dev, ret, "Unable to get battery info\n");
|
|
|
|
platform_set_drvdata(pdev, bat);
|
|
|
|
return 0;
|
|
|
|
comm_error:
|
|
return dev_err_probe(dev, ret, "Unable to communicate with device\n");
|
|
}
|
|
|
|
static int pm8916_bms_vm_battery_suspend(struct platform_device *pdev, pm_message_t state)
|
|
{
|
|
struct pm8916_bms_vm_battery *bat = platform_get_drvdata(pdev);
|
|
int ret;
|
|
|
|
/*
|
|
* Due to a hardware quirk the FSM doesn't switch states normally.
|
|
* Instead we unlock the debug registers and force S3 (Measure OCV/Sleep)
|
|
* mode every time we suspend.
|
|
*/
|
|
|
|
ret = regmap_write(bat->regmap,
|
|
bat->reg + PM8916_SEC_ACCESS, PM8916_SEC_MAGIC);
|
|
if (ret)
|
|
goto error;
|
|
ret = regmap_write(bat->regmap,
|
|
bat->reg + PM8916_BMS_VM_MODE_CTL, PM8916_BMS_VM_MODE_FORCE_S3);
|
|
if (ret)
|
|
goto error;
|
|
|
|
return 0;
|
|
|
|
error:
|
|
dev_err(bat->dev, "Failed to force S3 mode: %pe\n", ERR_PTR(ret));
|
|
return ret;
|
|
}
|
|
|
|
static int pm8916_bms_vm_battery_resume(struct platform_device *pdev)
|
|
{
|
|
struct pm8916_bms_vm_battery *bat = platform_get_drvdata(pdev);
|
|
int ret;
|
|
unsigned int tmp;
|
|
|
|
ret = regmap_bulk_read(bat->regmap,
|
|
bat->reg + PM8916_BMS_VM_S3_S7_OCV_DATA0, &tmp, 2);
|
|
|
|
bat->last_ocv_time = ktime_get_seconds();
|
|
bat->last_ocv = tmp * 300;
|
|
|
|
ret = regmap_write(bat->regmap,
|
|
bat->reg + PM8916_SEC_ACCESS, PM8916_SEC_MAGIC);
|
|
if (ret)
|
|
goto error;
|
|
ret = regmap_write(bat->regmap,
|
|
bat->reg + PM8916_BMS_VM_MODE_CTL, PM8916_BMS_VM_MODE_NORMAL);
|
|
if (ret)
|
|
goto error;
|
|
|
|
return 0;
|
|
|
|
error:
|
|
dev_err(bat->dev, "Failed to return normal mode: %pe\n", ERR_PTR(ret));
|
|
return ret;
|
|
}
|
|
|
|
static const struct of_device_id pm8916_bms_vm_battery_of_match[] = {
|
|
{ .compatible = "qcom,pm8916-bms-vm", },
|
|
{}
|
|
};
|
|
MODULE_DEVICE_TABLE(of, pm8916_bms_vm_battery_of_match);
|
|
|
|
static struct platform_driver pm8916_bms_vm_battery_driver = {
|
|
.driver = {
|
|
.name = "pm8916-bms-vm",
|
|
.of_match_table = pm8916_bms_vm_battery_of_match,
|
|
},
|
|
.probe = pm8916_bms_vm_battery_probe,
|
|
.suspend = pm8916_bms_vm_battery_suspend,
|
|
.resume = pm8916_bms_vm_battery_resume,
|
|
};
|
|
module_platform_driver(pm8916_bms_vm_battery_driver);
|
|
|
|
MODULE_DESCRIPTION("pm8916 BMS-VM driver");
|
|
MODULE_AUTHOR("Nikita Travkin <nikita@trvn.ru>");
|
|
MODULE_LICENSE("GPL");
|